The radius of Mohr's circle is approximately 671.05 MPa
To determine the radius of the mohr's circle?
We need to apply the following calculation to determine Mohr's circle's radius:
r = sqrt((σ1 - σ2)^2/4 + τ^2)
Where is the shear stress and 1 and 2 are the two normal stresses.
With the values from the problem substituted, we obtain:
r = sqrt((473 - (-473))^2/4 + 478^2)
r = sqrt(473^2 + 478^2)
r = sqrt(450409)
Therefore, the radius of Mohr's circle is approximately 671.05 MPa
Learn more about radius here : brainly.com/question/28162977
#SPJ1
1. Explain what is wrong with the encryption scheme used by WEP.
2. Describe the authentication protocol that WEP employs to authenticate a wireless host to a wireless AP (given that the two have a pre-shared symmetric key). Show an attack on this protocol. That is, show how an attacker, who does not have access to the key shared between a host and an AP, can impersonate the host
1. WEP's encryption scheme is wrong because of weak key management, the use of RC4 algorithm with no integrity protection, and vulnerable initialization vector (IV) management.
2. WEP uses Open System Authentication with a pre-shared key, but it's susceptible to a Fake AP attack. Here, an attacker can easily attack when he creates a rogue AP with the same Service Set Identifier (SSID), capturing the Authentication frame, and impersonating the legitimate host to gain unauthorized access.
What is WEP?WEP or Wired Equivalent Privacy refers to a security protocol used for encrypting and protecting data transmitted over wireless networks.
WEP was initially designed to provide a level of privacy and security to encrypt and protect data for a wireless network, but it is no longer considered secure because of its weakness.
Learn more about WEP at brainly.com/question/13068626
#SPJ4
8. What occupancies did Local Law 41 /78 require retroactive sprinkler protection?
Local Law 41/78 required retroactive sprinkler protection for multiple-dwelling buildings, hotels, and high-rise office buildings over 100 feet tall.
What is Local Law 41/78?Local Law 41/78 is a law passed in New York City in 1978 that required the retrofitting of automatic sprinkler systems in certain types of buildings. The law was enacted in response to a series of tragic fires that occurred in the city, including the 1975 fire at the historic Stouffer's Inn, which claimed the lives of 15 people.
Under the law, multiple-dwelling buildings, hotels, and high-rise office buildings over 100 feet tall were required to install automatic sprinkler systems within a specified timeframe. The law also mandated that these buildings undergo regular fire safety inspections, and established penalties for noncompliance.
Local Law 41/78 is considered a landmark piece of legislation that has significantly improved fire safety in New York City, and has served as a model for similar laws in other cities and states across the country.
Learn more about Sprinkler protection, here:
https://brainly.com/question/18650667
#SPJ4
a residential lighting branch circuit is to be loaded at no more than 80% of its capacity. if the circuit is operating at 120v and is rated at 12a, what is the maximum initial connected load?
The maximum Initial connected load for the residential building is
1,152 VA How to find the maximum initial connected loadFor a residential lighting branch circuit, the following calculation must be used to determine the maximum initial connected load:
Maximum initial connected load is calculated as (Rated amperage x Voltage).
Given data: circuit is operating at 120v and is rated at 12a
Maximum initial connected load = (12A x 120V)
Maximum initial connected load = 1,152 VA
Therefore, the maximum initial connected load is 1,152VA
Learn more about Maximum load at
https://brainly.com/question/31274355
#SPJ4
What metric could be used to make a quantitative calculation of risk due to a specific threat to a specific function or asset?
One metric that could be used to make a quantitative calculation of risk due to a specific threat to a specific function or asset is the annualized loss expectancy (ALE).
One metric that could be used to make a quantitative calculation of risk due to a specific threat to a specific function or asset is the annualized loss expectancy (ALE). ALE takes into account the probability of the threat occurring and the potential financial loss associated with it. This metric can provide a numerical value that can be used to prioritize risk management efforts and allocate resources accordingly. It is a commonly used metric in risk management and can be helpful in identifying potential vulnerabilities and developing mitigation strategies.
Learn more about (ALE) here
https://brainly.com/question/29851249
#SPJ11
Drawing 15.40:
Assuming an ideal drawing process, what is the smallest final diameter to which a
60-mm diameter rod can be drawn?
To calculate the smallest final diameter of a 60-mm diameter rod in an ideal drawing process, we will use the following steps:
1. Identify the initial diameter: The initial diameter of the rod is 60 mm.
2. Identify the drawing process terms: We are asked to calculate the smallest final diameter in an ideal drawing process.
3. Apply the ideal drawing process assumption: In an ideal drawing process, there is no limit to the amount of reduction that can be achieved. Therefore, the smallest final diameter can theoretically be reduced to an infinitesimally small value.
In conclusion, assuming an ideal drawing process, the smallest final diameter to which a 60-mm diameter rod can be drawn is theoretically infinitesimally small. However, in real-world applications, there will be practical limitations and material properties that would prevent such extreme reductions.
To know more about ideal drawing process
https://brainly.com/question/31579049?
#SPJ11
Outline two ways a higher level language may be different
There are several ways in which a higher-level language may differ from a lower-level language. Here are two examples:
AbststractionPortability
1. Abstraction: One of the key features of higher-level languages is abstraction. This means that the language provides high-level constructs that allow developers to work at a higher level of abstraction, without having to worry about the low-level details of the underlying hardware. For example, in a higher-level language like Python, you can work with lists, dictionaries, and other high-level data structures without having to worry about how they are implemented in memory. This makes it easier for developers to write more expressive and maintainable code.
2. Portability: Another way in which higher-level languages may differ is in their portability. Higher-level languages are often designed to be platform-independent, meaning that they can be run on different types of hardware and operating systems without modification. This is in contrast to lower-level languages like assembly language, which are often tied to a specific architecture and operating system. The portability of higher-level languages makes them more accessible and widely used, as they can be used to write software that can be run on a variety of devices and platforms.
Learn More about lower-level language here :-
https://brainly.com/question/31412555
#SPJ11
Can you install MegaPress on epoxy coated steel pipe?
Yes, it is correct to state that Viega MegaPress Fittings can be installed on different types of steel pipe including epoxy-coated steel pipe.
What is the explanation for the above response?According to the maker, Viega, MegaPress fittings can be installed on different types of steel pipes, which include epoxy coated stell pipe.
Note however, that for epoxy-coatings, the surface must be fully cured and the surface must be clean and without dust before the fittings are installed.
Hence, it is correct to state that Viega MegaPress Fittings can be installed on different types of steel pipe including epoxy-coated steel pipe.
Learn more about steel pipe at:
https://brainly.com/question/16414540
#SPJ1
What indicator is biased to flaps pos.
The indicator that is biased toward flap position is the flap position indicator. This instrument displays the current position of the flaps on an aircraft, which can be useful for pilots during takeoff and landing maneuvers. However, it is important to note that this indicator may be subject to biases or errors, so pilots should always cross-check their instruments and use good judgment when operating the aircraft.
It seems that you are asking about an indicator related to the position of flaps on an aircraft. In this context, the terms you mentioned can be explained as follows:
1. Indicator: A device that displays information or measurement, such as the position of flaps on an aircraft.
2. Biased: Inaccurate or misleading due to a systematic error or partiality.
3. Flaps Pos: The position of the flaps on an aircraft's wings, which are adjustable surfaces used for control and stability during different flight phases.
Your question asks about an indicator that is biased to flaps position. It could be interpreted as a flap position indicator that might provide misleading or inaccurate information about the actual position of the flaps. To address this issue, it is essential to ensure proper maintenance and calibration of the flap position indicator to avoid any biased readings that may impact flight safety.
to know more about indicator :
https://brainly.com/question/20264817
#SPJ11
If an electric heater has three heating elements connected in parallel, why does each element have its own fusible link and limit switch?
An electric heater with three heating elements connected in parallel has each element's own fusible link and limit switch for the following reasons:
How can we explain this?
1. Safety: Each fusible link serves as a safety device that breaks the electrical circuit for its corresponding element if the current exceeds a specified level. This helps prevent overheating, fire hazards, or damage to the individual elements.
2. Independent operation: Having separate fusible links and limit switches allows each heating element to operate independently. If one element fails or reaches its temperature limit, the other elements can continue to provide heat without being affected.
3. Load balancing: In a parallel connection, the current is divided among the elements. Separate fusible links ensure that each element receives the appropriate amount of current for its intended operation, preventing imbalances that could lead to overheating or reduced performance.
4. Easier troubleshooting: If an issue arises with one of the heating elements, having its own fusible link and limit switch makes it easier to identify and address the problem without affecting the entire system.
In summary, having individual fusible links and limit switches for each heating element in an electric heater connected in parallel ensures safe, independent operation, load balancing, and easier troubleshooting.
to know more about Safety:
https://brainly.com/question/30671888
#SPJ11
4. Which condition(s) of a material will produce burning of the material?
A material must reach its ignition temperature and come into contact with an oxidizer to produce burning.
What is ignition temperature?The ignition temperature of a material is the minimum temperature at which the material will self-ignite and sustain combustion in the presence of an oxidizer, such as air. This temperature varies depending on the type of material, its physical state, and the surrounding conditions, such as pressure and humidity.
When a material is heated, its temperature rises until it reaches the ignition temperature, at which point it begins to undergo combustion. The heat generated by the initial reaction provides energy to sustain the combustion process, producing flames and releasing heat and light.
Learn more about ignition temperature, here:
https://brainly.com/question/12973968
#SPJ4
Eye and face protection must be stamped _____ to indicate that the ppe meets this specification for the design.
A. ansi 87.1
B. Astm 4000
C. osha 29cfr
D. none
Eye and face protection must be stamped with "A. ANSI Z87.1" to indicate that the PPE meets this specification for the design. This standard ensures that the PPE provides adequate protection for the user.
What is eye and face protection?
Eye and face protection refers to equipment designed to protect the eyes and face from various hazards, such as flying debris, chemicals, radiation, and other types of potentially harmful substances or conditions.
Eye protection can include safety glasses, goggles, face shields, welding helmets, and full-face respirators, among others. These types of equipment are used in a variety of industries, including construction, manufacturing, healthcare, and laboratory settings.
Face protection can include face shields, welding shields, and other types of equipment that cover the face to protect it from hazards such as chemical splashes, flying debris, and radiation. Some types of face protection may also provide respiratory protection, such as full-face respirators that protect against harmful dusts, gases, or vapors.
It's important to wear appropriate eye and face protection whenever there is a risk of injury to the eyes or face from hazards in the workplace. Proper use of eye and face protection can help prevent serious injuries or even permanent damage to the eyes and face.
to know more about healthcare:
https://brainly.com/question/12881855
#SPJ11
Query all columns (attributes) for every row in the CITY table.
To query all columns (attributes) for every row in the CITY table, you will need to use the SELECT statement in SQL. The SELECT statement is used to retrieve data from a table or a view in a database.
To retrieve all columns for every row in the CITY table, you would use the following SQL query:
SELECT * FROM CITY;
The asterisk (*) in the SELECT statement represents all columns in the table. This will retrieve all the data in every row of the CITY table.
It is important to note that when using the SELECT statement, you can specify which columns you want to retrieve by listing them out after the SELECT keyword, separated by commas. For example, if you only wanted to retrieve the name and population columns for every row in the CITY table, your SQL query would look like this:
SELECT name, population FROM CITY;
In conclusion, to retrieve all columns for every row in the CITY table, you would use the SQL query "SELECT * FROM CITY".
For such more question on keyword
https://brainly.com/question/26355510
#SPJ11
In a SMAW electrode, the "1" refers to:
A) Electrode type
B) Coating characteristics
C) Chemical composition
D) Welding position
In a SMAW electrode, the "1" refers to Electrode type. The correct option is A.
A consumable electrode wrapped in a flux is used in shielded metal arc welding (SMAW), sometimes referred to as manual metal arc welding (MMA or MMAW), flux shielded arc welding, or simply as stick welding.
An electric arc is created between the electrode and the metals to be connected using an electric current, either in the form of direct current or alternating current from a welding power supply.
The junction is created when the workpiece and electrode melt, creating a pool of molten metal known as the "weld pool." As the weld is being laid, the electrode's flux covering disintegrates, releasing vapors that act as a shielding gas and creating a layer.
Thus, The ideal option is A.
Learn more about SMAW, refer to the link:
https://brainly.com/question/18125312
#SPJ4
Declare a variable of the enumeration type HvacStatus named systemStatus.
To declare a variable of the enumeration type HvacStatus named systemStatus, follow these steps:
Step 1: Define the enumeration type HvacStatus with possible values.
For example, let's assume we have three possible states: Off, Cooling, and Heating.
```csharp
public enum HvacStatus
{
Off,
Cooling,
Heating
}
```
Step 2: Declare the variable named systemStatus of type HvacStatus.
```csharp
HvacStatus systemStatus;
```
In the first step, we define the HvacStatus enumeration type which contains the possible states of an HVAC system. In the second step, we declare the variable systemStatus of the previously defined enumeration type HvacStatus. This variable can now be used to store and manipulate the HVAC system's status throughout the program.
Learn more about enumeration type: https://brainly.com/question/30175685
#SPJ11
MegaPress Carbon Steel fittings with Green Dots can be used in potable water applications?
Yes, MegaPress Carbon Steel fittings with Green Dots can be used in potable water applications. The Green Dot indicates that the fitting is lead-free and meets the requirements for potable water applications.
It is important to follow all manufacturer instructions and local codes and regulations when installing and using these fittings.
MegaPress Carbon Steel fittings with green dots are not suitable for potable water applications. These fittings are designed for use in gas and mechanical systems. For potable water applications, it is recommended to use fittings specifically designed and approved for that purpose, such as those made from copper or other materials compatible with drinking water systems.
Learn More about MegaPress here :-
https://brainly.com/question/31597386
#SPJ11
Where are structural bays located in typical high-rise buildings that can accommodate heavier loads?
In typical high-rise buildings, structural bays that can accommodate heavier loads are located in the building's core and at the perimeter. The core is a central vertical column that provides stability and support for the entire structure, while the perimeter columns transfer the loads from the floors to the foundation. These two areas work together to distribute the weight and provide structural integrity for the building.
Structural bay means the distance or span from one vertical structural member fronting on a street to the immediately adjacent vertical structural member fronting on the same street.
To know more about structural bays
https://brainly.com/question/26625076
#SPJ11
The following statements that correctly describe plastic deformation in crystalline materials:
statements about plastic deformation in crystalline materials: Plastic deformation involves the permanent change in shape or size of a material without breaking or fracturing.
It occurs when the applied stress exceeds the material's yield strength. During plastic deformation, dislocations in the crystal lattice move and interact, causing slip or glide of crystal planes. This slip allows the material to undergo plastic deformation by changing its shape without breaking. Plastic deformation in crystalline materials is typically a gradual and progressive process, occurring over a range of stresses and strains, and can result in significant changes in the material's shape and mechanical properties.
Plastic deformation in crystalline materials can be influenced by various factors, such as temperature, strain rate, crystal orientation, and the presence of impurities or defects in the crystal lattice.
Plastic deformation in crystalline materials can result in the formation of new dislocations, as well as the rearrangement .
learn more about crystalline materials here:
https://brainly.com/question/30343293
#SPJ11
When pole vaulting, a pole achieves a minimum radius of curvature estimated to be 5. 0 m. The pole has an OD of 40 mm and an ID of 15 mm and is made of fiberglass with an of E= 69 GPa and a yield stress of 3 GPa
a. The max strain develop in the pole at bmax/E = ymax / R
b. The value of the max strain is 4 × 10^-3
c. The max stress at this same location is 276mpa.
d. The factor of safety with this stress is 10.86.
What is Max strain?Max strain, or the Point of Breakdown (POB), refers to the greatest degree of deformity that a material can be subject to, prior to enduring permanent damage. Strain stands as a signal of an item's alteration in shape under pressure, and is generally shown as a percentage or decimal rate compared to the material's initial size.
The utmost strain an object is able to sustain is contingent upon its mechanical characterstics such as ultimate strength, yield strength, and ductility. These properties are impacted by dynamics including the material's elements, microstructure, and processing chronicle.
Learn more about strain on
https://brainly.com/question/17046234
#SPJ4
1-How often do you test a water flow alarm device in a sprinkler system?
2- How often should a gauge on a non-supervised dry sprinkler system be inspected?
1- Water flow alarm devices in sprinkler systems should be tested annually in accordance with NFPA 25.
2- Gauges on non-supervised dry sprinkler systems should be inspected every five years in accordance with NFPA 25.
What is sprinkler system?A sprinkler system is an automatic fire protection system that uses a network of pipes, valves, and sprinkler heads to deliver water or other extinguishing agents to control or extinguish a fire. Sprinkler systems are designed to detect a fire in its early stages and automatically activate, distributing water or other extinguishing agents to the affected area.
There are several types of sprinkler systems, including wet pipe systems, dry pipe systems, pre-action systems, and deluge systems. Each system is designed for specific types of hazards and environments, and must be installed and maintained in accordance with applicable codes and standards, such as NFPA 13: Standard for the Installation of Sprinkler Systems.
Regular inspections, testing, and maintenance of sprinkler systems are essential to ensure their proper operation in the event of a fire.
Learn more about Sprinkler system, here:
https://brainly.com/question/30777999
#SPJ4
You are preparing some notes on diversity strategies for cybersecurity resilience for the executive team. You have prepared sections on technologies, crypto, and controls so far. What other topic do you need to cover?
In addition to the sections on technologies, crypto, and controls, there are several other important topics that should be included in your notes on diversity strategies for cybersecurity resilience. One critical area to cover is the importance of promoting diversity and inclusion within the cybersecurity workforce. This can involve implementing strategies to attract and retain a diverse pool of talent, as well as providing training and support for underrepresented groups to help them advance within the field. Other key topics to consider include the role of collaboration and information sharing in promoting cybersecurity resilience, as well as the need to stay up-to-date on emerging threats and technologies in order to effectively mitigate risks. Ultimately, a comprehensive approach to diversity strategies for cybersecurity resilience should encompass a range of different tactics and initiatives, all aimed at building a more robust and resilient cybersecurity posture.
To know more about cybersecurity resilience
https://brainly.com/question/31578515?
#SPJ11
Can you install Socket Am3 or AM2+ processors in Socket AM2 motherboards?
Yes, you can install Socket AM3 or AM2+ processors on Socket AM2 motherboards, as long as the motherboard supports the particular processor you are attempting to install. However, it is always recommended to check the motherboard specifications and compatibility before attempting to install a new processor.
How can we explain socket AM3 or AM2+ processors?
Sockets AM3 and AM2+ are two types of CPU sockets used by AMD processors in desktop computers. These sockets are used to connect the processor to the motherboard and provide a high-speed communication pathway between the CPU and other components of the computer.
Socket AM3 was introduced in 2009 and is used by AMD processors like the Phenom II, Athlon II, and Sempron 100 series. This socket supports both DDR2 and DDR3 memory, making it a versatile choice for computer builders. Socket AM3 processors are also backwards compatible with AM2+ motherboards, although this may require a BIOS update.
Socket AM2+ was introduced in 2007 and is used by AMD processors like the Phenom X3, Phenom X4, Athlon 64 X2, and Sempron. This socket supports DDR2 memory, which was a popular memory technology at the time.
Both Socket AM3 and AM2+ support HyperTransport, a high-speed communication protocol that allows the processor to communicate with other components of the computer, such as the Northbridge, Southbridge, and memory.
When selecting a processor and motherboard for a desktop computer, it is important to choose components that are compatible with each other. This means selecting a processor that uses the same socket as the motherboard, and ensuring that the motherboard supports the specific features and capabilities of the processor.
In summary, Socket AM3 and AM2+ are two types of CPU sockets used by AMD processors in desktop computers. These sockets provide a high-speed communication pathway between the CPU and other components of the computer, and support different memory technologies. When selecting components for a desktop computer, it is important to choose components that are compatible with each other.
to know more about HyperTransport:
https://brainly.com/question/30587029
#SPJ11
Outline how a sub-procedure can be considered an example of abstraction.
A sub-procedure can be considered an example of abstraction by simplifying complex tasks and hiding the details of implementation. In this process, a sub-procedure serves as a smaller, self-contained piece of code that performs a specific function within a larger program.
Here's a step-by-step explanation:
1. Identify the specific task: In a large program, there may be a task that needs to be executed multiple times or in different parts of the program. This task can be represented as a sub-procedure.
2. Create a sub-procedure: Write a separate piece of code for the task, which can be called or invoked by the main program whenever needed. This sub-procedure will include the necessary inputs, outputs, and operations required for the task.
3. Implement abstraction: The sub-procedure serves as an abstraction because it hides the details of how the task is carried out. The main program does not need to know the specific implementation details; it only needs to know how to call the sub-procedure and provide the required inputs.
4. Reusability: This abstraction allows the sub-procedure to be easily reused in other parts of the program, simplifying the code and reducing duplication.
In summary, a sub-procedure is an example of abstraction because it simplifies complex tasks by hiding implementation details, allowing for easier reuse and better organization of code.
Learn more about Abstraction here:- brainly.com/question/7994244
#SPJ11
fill in the blank. ____is the most effective, economical and widely used methods of soil improvement and densification.
Compaction
Answer:
Dynamic compaction
Explanation:
Dynamic compaction is an efficient and cost-effective soil improvement technique that uses the dynamic effect of high energy impacts to densify weak soil. The dynamic effect is generated by dropping a static weight (15-40 tones) from a defined height (10-30 m).
During a fire, when may a multi-bank elevator be used?
A. when they serve the fire floor
B. when smoke-free
C. when cars manned by trained building personnel or firefighters
D. never during a fire
A multi-bank elevator be used During a fire when when cars manned by trained building personnel or firefighters.
Why may A multi-bank elevator be used During a fire due to the presence of building personnel or firefighters?Using an elevator when there is a fire might be risky since they could break down and expose people to smoke or heat.
Multi-bank elevators may, however, be used in specific circumstances if they are operated by skilled building staff or firefighters who can guarantee safe operation and escape during the fire.
During a fire emergency, it is essential to follow the directions of emergency officials and building safety regulations.
Find more exercises regarding trained building personnel or firefighters;
https://brainly.com/question/24462816
#SPJ1
04-009 - List 3 logical condition symbols
3 logical condition symbols.
Here they are:
1. ∧ (AND): This symbol represents the logical "AND" operation. Both conditions must be true for the entire expression to be true.
2. ∨ (OR): This symbol represents the logical "OR" operation. At least one of the conditions must be true for the entire expression to be true.
3. ¬ (NOT): This symbol represents the logical "NOT" operation. It negates the truth value of a condition. If the condition is true, it becomes false, and if it's false, it becomes true.
These symbols are used in logical expressions to build more complex conditions and analyze their truth values.
To know more about logical condition symbols.
https://brainly.com/question/16679676?
#SPJ11
AMD Sockets: AM2+ has how many pins and supports what?
The AMD Socket AM2+ has 940 pins and supports DDR2 memory. It is compatible with AMD Phenom, Athlon 64, and Sempron processors.
"AMD socket" refers to the physical interface between an AMD processor and its corresponding motherboard. AMD has used a variety of sockets over the years, each with different pin layouts and specifications.
Some of the most common AMD sockets include:
AM4: This is the current mainstream socket used by AMD's Ryzen and A-series processors. It has 1331 pins and supports DDR4 memory.
TR4: This socket is used by AMD's high-end desktop processors, including the Threadripper and Epyc series. It has 4094 pins and supports quad-channel DDR4 memory.
FM2+: This socket is used by AMD's A-series and Athlon processors. It has 906 pins and supports DDR3 and DDR4 memory.
AM3+: This socket is used by AMD's FX-series processors. It has 941 pins and supports DDR3 memory.
Socket A: This was a popular socket used by AMD's Athlon and Duron processors in the early 2000s. It had 462 pins and supported DDR memory.
The specific socket required for a particular AMD processor depends on the generation and model of the processor. It's important to verify compatibility between the processor and motherboard before making a purchase.
to know more about Socket :
https://brainly.com/question/29658250
#SPJ11
tech a states that transmissions and transaxles are completely different, and share nothing in common. tech b states that if we are discussing ring and pinion backlash, that can apply only to a transaxle. who is correct?
Non of these technician is correct in the argument that is presented here
How to determine the correct technicianThe first technician is not correct. The reason is because he said that transmissions and transaxles are completely different. This is wrong because both are designed to be able to share components such as their gears
The second is also incorrect because he said that the ring and pinion backlash, that can apply only to a transaxle. The ring and the pinion are found the front rear of wheel.
Read more on technicians here:https://brainly.com/question/18428188
#SPJ4
a no. 207 radial-contact ball bearing carries a combined load of 300 lb radially and 150 lb axially at 2000 rpm. the bearing is subjected to uniform loading. find the expected bearing life in hours if we want only a 4% chance of failure. can you increase the thrust load on this bearing and keep the same bearing life? if you can, how much more thrust load can you add to this bearing?
The expected bearing life in hours if we want only a 4% chance of failure is 3.7 hours.
What is the expected bearing life?Naturally, the longevity of a bearing can fluctuate depending on multiple aspects such as its kind, running environs, and upkeep technologies. To ascertain presumed life-cycles beneath explicit stipulations, manufacturers of bearings will habitually provide evaluations developed from empiric trials and assessing.
Life in accord to the L10 index remains the most commonly established measure of a bearing's usefulness; whereby an assembly must endure a given amount of revolutions before 10% have succumbed to weariness. Regard to strain, momentum, lubrication, temperature, and toxins further contribute prominently towards an L10 life test.
Learn more about bearing on
https://brainly.com/question/22715853
#SPJ4
ne advantage of cmos logic is its low power dissipation. p2.2 consider the drain currents i d1 and id2 flowing in the transistors m1 and m2. assuming there is no load on vcomp , what are the approximate drain currents when vclk is high? when vclk is low? when does a significant amount of drain current flow?
When voltage indicator, VCLK, alters from high to low or vice versa in a transistor, a huge amount of drain current streams through the conductor.
Advantage of cmos logicAlthough, during the transition state, there could be a noticeable sum of energy dissipation due to the sizeable crowbar current.
CMOS logic systems possess an superiority when it comes to resembling low power consumption as they consume paltry energy when the transistors are in a constant condition i.e., when VCLK is either high or low.
Learn more about voltage on
https://brainly.com/question/1176850
#SPJ4
There are two compaction tests routinely carried out in the lab to obtain the maximum dry density and optimum moisture content of soils
The two compaction tests routinely carried out in the lab to obtain the maximum dry density and optimum moisture content of soils, these tests are:
1. Standard Proctor Test (ASTM D698)
2. Modified Proctor Test (ASTM D1557)
The purpose of these tests is to determine the relationship between the moisture content and dry density of the soil sample, which helps in understanding the soil's compaction behavior.
Step-by-step explanation:
1. Prepare the soil sample by sieving it through a specific size sieve (4.75mm for Standard Proctor and 19mm for Modified Proctor).
2. Add water to the soil to reach the desired moisture content.
3. Fill the soil into the Proctor mold in three layers for Standard Proctor or five layers for Modified Proctor.
4. Compact each layer of soil with a specified number of blows (25 for Standard Proctor and 56 for Modified Proctor) using a specific weight hammer (2.5 kg for Standard Proctor and 4.5 kg for Modified Proctor).
5. After compaction, remove the mold and trim the soil to obtain a uniform surface.
6. Weigh the compacted soil and calculate its wet density.
7. Take a small sample from the compacted soil, oven-dry it, and calculate its dry density and moisture content.
8. Repeat the process with different moisture contents.
9. Plot the dry density versus moisture content graph to determine the maximum dry density and optimum moisture content.
In summary, the Standard Proctor Test and Modified Proctor Test are the two compaction tests routinely carried out in the lab to obtain the maximum dry density and optimum moisture content of soils.
To know more about compaction tests
https://brainly.com/question/24052398?
#SPJ11